• English
    • Welsh
  • English 
    • English
    • Welsh
  • Login
Search DSpace:
  • Home
  • Research at Cardiff Met
  • Library Services
  • Contact Us
View item 
  • DSpace home
  • Cardiff School of Sport and Health Sciences
  • Import
  • View item
  • DSpace home
  • Cardiff School of Sport and Health Sciences
  • Import
  • View item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Validity and Reliability of Surface Electromyography Measurements from a Wearable Athlete Performance System

Thumbnail
View/open
Publisher's PDF (760.7Kb)
Author
Lynn, Scott
Watkins, Casey
Wong, Megan
Balfany, Katherine
Feeney, Daniel
Date
2018-05-14
Acceptance date
2018-02-27
Type
Article
Publisher
University of Uludag
ISSN
1303-2968
Metadata
Show full item record
Abstract
The Athos ® wearable system integrates surface electromyography (sEMG ) electrodes into the construction of compression athletic apparel. The Athos system reduces the complexity and increases the portability of collecting EMG data and provides processed data to the end user. The objective of the study was to determine the reliability and validity of Athos as compared with a research grade sEMG system. Twelve healthy subjects performed 7 trials on separate days (1 baseline trial and 6 repeated trials). In each trial subjects wore the wearable sEMG system and had a research grade sEMG system’s electrodes placed just distal on the same muscle, as close as possible to the wearable system’s electrodes. The muscles tested were the vastus lateralis (VL), vastus medialis (VM), and biceps femoris (BF). All testing was done on an isokinetic dynamometer. Baseline testing involved performing isometric 1 repetition maximum tests for the knee extensors and flexors and three repetitions of concentric-concentric knee flexion and extension at MVC for each testing speed: 60, 180, and 300 deg/sec. Repeated trials 2-7 each comprised 9 sets where each set included three repetitions of concentric-concentric knee flexion-extension. Each repeated trial (2-7) comprised one set at each speed and percent MVC (50%, 75%, 100%) combination. The wearable system and research grade sEMG data were processed using the same methods and aligned in time. The amplitude metrics calculated from the sEMG for each repetition were the peak amplitude, sum of the linear envelope, and 95th percentile. Validity results comprise two main findings. First, there is not a significant effect of system (Athos or research grade system) on the repetition amplitude metrics (95%, peak, or sum). Second, the relationship between torque and sEMG is not significantly different between Athos and the research grade system. For reliability testing, the variation across trials and averaged across speeds was 0.8%, 7.3%, and 0.2% higher for Athos from BF, VL and VM, respectively. Also, using the standard deviation of the MVC normalized repetition amplitude, the research grade system showed 10.7% variability while Athos showed 12%. The wearable technology (Athos) provides sEMG measures that are consistent with controlled, research grade technologies and data collection procedures.
Journal/conference proceeding
Journal of Sports Science and Medicine;
Citation
Lynn, S.K., Watkins, C.M., Wong, M.A., Balfany, K. and Feeney, D.F. (2018) 'Validity and Reliability of Surface Electromyography Measurements from a Wearable Athlete Performance System', Journal of Sports Science & Medicine, 17(2), p.205.
URI
https://www.jssm.org/hf.php?id=jssm-17-205.xml
http://hdl.handle.net/10369/10460
Description
Article published in Journal of Sports Science & Medicine on 14 May 2018 (online), available open access at: https://www.jssm.org/hf.php?id=jssm-17-205.xml.
Rights
https://creativecommons.org/licenses/by-nc-nd/4.0/
Sponsorship
Cardiff Metropolitan University (Grant ID: Cardiff Metropolian (Internal))
Collections
  • Import [796]

Related items

Showing items related by title, author, subject and abstract.

  • Thumbnail

    An investigation into the use of wearable technologies for wellness and health case studying young adults at CMU. 

    White, James (Cardiff Metropolitan University, 2017-04)
    With the rapid grown of the wearable technology industry has come a vast array of available products to suit almost any individual’s needs. This dissertation investigates and establishes the views that people in the Cardiff ...
  • Thumbnail

    Reliability of Sprint Acceleration Performance and Three Repetition Maximum Back Squat Strength in Hurling Players 

    Bryne, Paul; Moody, Jeremy A.; Cooper, Stephen-Mark; Kinsella, Sharon (ARC, 2018)
    The purpose of this study was to estimate the inter-day reliability of 5, 10 and 20-meter sprint time and three repetition maximum back squat strength in male hurling players. Eighteen male hurling players volunteered to ...
  • Thumbnail

    The Effect Of Different Conditioning Contraction Loading on Post-Activation Potentiation. 

    Penny, Blake (Cardiff Metropolitan University, 2015)
    A muscle’s ability to generate force and velocity is determined by several components which are a consequence of its contractile history; however, this has been shown to be acutely yet significantly influenced following ...

Browse

DSpace at Cardiff MetCommunities & CollectionsBy issue dateAuthorsTitlesSubjectsThis collectionBy issue dateAuthorsTitlesSubjects

My Account

Login

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

DSpace software copyright © 2002-2015  DuraSpace
Contact us | Send feedback | Administrator