dc.identifier.citationAlam, M., Singh, H., Suresh, S. and Redpath, D.A.G. (2017) 'Energy and economic analysis of Vacuum Insulation Panels (VIPs) used in non-domestic buildings', Applied Energy, 188, pp.1-8. DOI: 10.1016/j.apenergy.2016.11.115.en_US
dc.identifier.issn0306-2619
dc.identifier.urihttp://hdl.handle.net/10369/10511
dc.descriptionArticle published in Applied Energy on 08 December 2016, available at: https://doi.org/10.1016/j.apenergy.2016.11.115.en_US
dc.description.abstractThe potential savings in space heating energy from the installation of Fumed Silica (FS) and Glass Fibre (GF) Vacuum Insulation Panels (VIPs) were compared to conventional expanded polystyrene (EPS) insulation for three different non-domestic buildings situated in London (UK). A discounted payback period analysis was used to determine the time taken for the capital cost of installing the insulation to be recovered. VIP materials were ranked using cost and density indexes. The methodology of the Payback analysis carried out considered the time dependency of VIP thermal performance, fuel prices and rental income from buildings. These calculations show that VIP insulation reduced the annual space heating energy demand and carbon dioxide (CO2) emissions by approximately 10.2%, 41.3% and 26.7% for a six storey office building, a two floor retail unit building and a four storey office building respectively. FS VIPs had the shortest payback period among the insulation materials studied, ranging from 2.5 years to 17 years, depending upon the rental income of the building. For GF VIPs the calculated payback period was considerably longer and in the case of the typical 4 storey office building studied its cost could not be recovered over the life time of the building. For EPS insulation the calculated payback period was longer than its useful life time for all three buildings. FS VIPs were found to be economically viable for installation onto non-domestic buildings in high rental value locations assuming a lifespan of up to 60 years.en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofseriesApplied Energy;
dc.titleEnergy and economic analysis of Vacuum Insulation Panels (VIPs) used in non-domestic buildingsen_US
dc.typeArticleen_US
dc.identifier.doihttps://doi.org/10.1016/j.apenergy.2016.11.115
dcterms.dateAccepted2016-11-28
rioxxterms.funderCardiff Metropolitan Universityen_US
rioxxterms.identifier.projectCardiff Metropolian (Internal)en_US
rioxxterms.versionAMen_US
rioxxterms.licenseref.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/en_US
rioxxterms.licenseref.startdate2019-05-20
rioxxterms.funder.project37baf166-7129-4cd4-b6a1-507454d1372een_US


Files in this item

Thumbnail

This item appears in the following collection(s)

Show simple item record