dc.identifier.citationZhao, F., Stephens, S.D.G., Ishak, W.S. and Meyer-Bisch, C. (2014) 'The characteristics of Audioscan and DPOAE measures in tinnitus patients with normal hearing thresholds', International Journal of Audiology, 53(5), pp.309-317.en_US
dc.identifier.issn1499-2027
dc.identifier.urihttp://hdl.handle.net/10369/7790
dc.descriptionThis article was published in International Journal of Audiology on 05 February 2014 (online), available at http://dx.doi.org/10.3109/14992027.2013.868047en_US
dc.description.abstractObjectives: To investigate auditory dysfunction in patients with tinnitus and normal hearing thresholds using two sensitive audiological measures. Design: The study was designed to investigate the characteristics of Audioscan and DPOAE tests in tinnitus patients with normal hearing thresholds. Audioscan and DPOAE notches were analysed and compared. All tests were performed in a sound-treated chamber or in a sound-treated room. Study sample: Forty-five tinnitus patients with normal hearing thresholds were examined following a written clinical protocol. Results: The averaged hearing levels obtained from tinnitus participants were significantly worse at high frequencies than those derived from the normative data. There was a significantly higher prevalence of Audioscan and DPOAE notches, whose central frequencies matched tinnitus frequencies in the mid-frequency regions, but not in the low- and high-frequency regions. A significant correlation was found between the centre frequencies of the Audioscan notches and the DPOAE notches from 500 to 4000 Hz. Conclusion: Tinnitus in different frequency regions may be associated with different underlying mechanisms of tinnitus generation. Some negative results on the Audioscan and DPOAE notches matching tinnitus pitches may be due to a limited set of discrete frequencies used for the tinnitus pitch matching test.en_US
dc.description.sponsorshipW.S. Ishak was supported by Ministry of Higher Education (MOHE) Malaysia and Universiti Kebangsaan Malaysia (UKM) as part of her PhD research at the University of Bristol, UKen_US
dc.language.isoenen_US
dc.publisherTaylor Francisen_US
dc.relation.ispartofseriesInternational Journal of Audiology
dc.subjectaudioscanen_US
dc.subjectDPOAEen_US
dc.subjectnotchesen_US
dc.subjecttinnitusen_US
dc.subjectnormal hearing thresholdsen_US
dc.titleThe characteristics of Audioscan and DPOAE measures in tinnitus patients with normal hearing thresholdsen_US
dc.typeArticleen_US
dc.identifier.doihttp://dx.doi.org/10.3109/14992027.2013.868047
dc.date.dateAccepted2013-11-18


Files in this item

Thumbnail

This item appears in the following collection(s)

Show simple item record