An investigation into the effects of in vitro dilution with different colloid resuscitation fluids on clot microstructure formation

Thumbnail
View/open
Author's post-print (501.2Kb)
Author
Lawrence, Matthew James
Marsden, Nick
Kaczynski, Jakub
Davies, Gareth
Davies, Nia
Hawkins, Karl
Perumal, Sounder
Brown, Martin Rowan
Morris, Keith
Davidson, Simon J.
Williams, Phylip Rhodri
Evans, Phillip Adrian
Date
2016-09-16
Acceptance date
2016-07-07
Type
Article
acceptedVersion
Publisher
Lippincott, Williams & Wilkins
ISSN
0003-2999
Metadata
Show full item record
Abstract
BACKGROUND: Balancing the beneficial effects of resuscitation fluids against their detrimental effect on hemostasis is an important clinical issue. We aim to compare the in vitro effects of 3 different colloid resuscitation fluids (4.5% albumin, hydroxyethyl starch [Voluven 6%], and gelatin [Geloplasma]) on clot microstructure formation using a novel viscoelastic technique, the gel point. This novel hemorheologic technique measures the biophysical properties of the clot and provides an assessment of clot microstructure from its viscoelastic properties. Importantly, in contrast to many assays in routine clinical use, the measurement is performed using unadulterated whole blood in a near-patient setting and provides rapid assessment of coagulation. We hypothesized that different colloids will have a lesser or greater detrimental effect on clot microstructure formation when compared against each other. METHODS: Healthy volunteers were recruited into the study (n = 104), and a 20-mL sample of whole blood was obtained. Each volunteer was assigned to 1 of the 3 fluids, and the sample was diluted to 1 of 5 different dilutions (baseline, 10%, 20%, 40%, and 60%). The blood was tested using the gel point technique, which measures clot mechanical strength and quantifies clot microstructure (d f) at the incipient stages of fibrin formation. RESULTS: d f and clot mechanical strength decrease with progressive dilution for all 3 fluids. A significant reduction in d f from baseline was recorded at dilutions of 20% for albumin (P < .0001), 40% for starch (P < .0001), and 60% for gelatin (P < .0001). We also observed significant differences, in terms of d f, when comparing the different types of colloid (P < .0001). We found that albumin dilution produced the largest changes in clot microstructure, providing the lowest values of d f (= 1.41 ± 0.061 at 60% dilution) compared with starch (1.52 ± 0.081) and gelatin (1.58 ± 0.063). CONCLUSIONS: We show that dilution with all 3 fluids has a significant effect on coagulation at even relatively low dilution volumes (20% and 40%). Furthermore, we quantify, using a novel viscoelastic technique, how the physiochemical properties of the 3 colloids exert individual changes on clot microstructure.
Journal/conference proceeding
Anesthesia & Analgesia;
Citation
Lawrence, M.J., Marsden, N., Kaczynski, J., Davies, G., Davies, N., Hawkins, K., Perumal, S., Brown, M.R., Morris, K., Davidson, S.J. and Williams, P.R. (2016) 'An Investigation Into the Effects of In Vitro Dilution With Different Colloid Resuscitation Fluids on Clot Microstructure Formation', Anesthesia & Analgesia, 123(5), pp.1081-1088.
URI
http://hdl.handle.net/10369/9243
DOI
http://dx.doi.org/10.1213/ANE.0000000000001536
Description
This article was published in Anesthesia & Analgesia on 16 September 2016 (online), available at http://dx.doi.org/10.1213/ANE.0000000000001536
Rights
https://creativecommons.org/licenses/by-nc/2.0/
Sponsorship
Cardiff Metropolitan University (Grant ID: Cardiff Metropolian (Internal))
Collections
  • Cardiovascular Health and Ageing [156]

Related items

Showing items related by title, author, subject and abstract.

  • Thumbnail

    A new structural biomarker that quantifies and predicts changes in clot strength and quality in a model of progressive haemodilution 

    Lawrence, Matthew J.; Kumar, Sendhil; Hawkins, Karl; Rutt, Harvey; Mills, Gavin; Sabra, Ahmed; Morris, Keith; Davidson, Simon J.; Badiei, Nafieseh; Brown, Martin R.; Williams, Phylip R.; Evans, Phillip A. (Elsevier, 2014-10-10)
    We investigated the effect of progressive haemodilution on the dynamics of fibrin clot formation and clot microstructure using a novel rheological method. The technique measures clotting time (TGP), clot strength (G`GP), ...
  • Thumbnail

    The Effect of Air Pollution Particles on Production of Interleukin-6 and Intracellular Adhesion Molecule by Monocytes and Endothelial Cells in Co-Culture on Cardiovascular Disease. 

    Williams, Rhys John (Cardiff Metropolitan University, 2017-06-01)
    Background A large majority of the current research has exposed mono cultured cells to particle matter (PM), then measuring their cytokine expressions. More recently, authors have advanced this to co-culture different ...
  • Thumbnail

    Pretraining Urine Osmolality, Sweat Loss, Fluid Intake and their Effects on Dehydration in British Division One Female Basketball Players During Training 

    Hardiman, Annabelle (University of Wales, 2011)
    The interindividual variability in the sweating responses and therefore fluid needs of athletes during exercise highlights the need for hydration guidelines to be developed on an individual basis. The following variables ...